This commit was manufactured by cvs2svn to create branch 'unlabeled-1.6.2'.
[mdsms.git] / mdsms.1.in
diff --git a/mdsms.1.in b/mdsms.1.in
deleted file mode 100644 (file)
index d645d68..0000000
+++ /dev/null
@@ -1,258 +0,0 @@
-.TH MDSMS 1 "17 May 1999" ~    VERSION ~ "SendSMS Manual"
-
-.\~ $Id$
-
-.SH NAME
-mdsms \- send SMSes through MobilDock
-
-.SH SYNOPSIS
-.B mdsms
-.RB [ "-c <cfgfile>" ]
-.RB [ "-d <device>" ]
-.RB [ "-L <file>" ]
-.RB [ "-l <lockfile>" ]
-.RB [ "-s <smsc #>" ]
-.RB [ "-m <#>" ]
-.RB [ "-r <sec>" ]
-.RB [ "-t <msec>" ]
-.RB [ "-T <msec>" ]
-.RB [ "\-fvhV" ]
-.RB [ "<dest. phone>" ]
-.RB [ "<msg text>" ]
-
-.SH DESCRIPTION
-Program sends one SMS message through MobilDock device.
-
-.SH OPTIONS
-.TP
-.BR -c | --config\  < cfgfile >
-Process recursively this file and read all options from it. See the section
-.B CONFIGURATION
-for more information.
-.TP
-.BR -d | --device\  < device >
-Specify serial device to communicate with MobilDock. If only bare name is
-specified, "\fB/dev/\fP" is prepended automatically. This device name is used
-subsequently with
-.BR -l | --lockfile
-option, see below.
-.TP
-.BR -L | --log\  < file >
-Log all important messages to this file preceded by timestamp, machine hostname
-etc., similar to output of
-.BR syslogd (8).
-If set to empty string (which is default - ~\fB        DEF_LOGNAME     \fP~), nothing
-is logged anywhere.
-.TP
-.BR -l | --lockfile\  < lockfile >
-Prior to accessing serial device specified above the lockfile should be
-acquired for correct concurrent processes behaviour. Although this name
-can be given as direct filename more common method is to use pattern
-with embedded "\fB%s\fP" where this mark is replaced by actual basename
-(last component of pathname with all preceding directory names stripped)
-of serial device used.
-Default name for lockfile is ~\fB      DEF_LOCKFILE    \fP~.
-.TP
-.BR -s | --smsc\  < smsc\ # >
-Specify custom SMS center number. If not specified (or overriden as empty
-string by \fB-s ""\fP)
-.B mdsms
-asks by "\fBAT+CSCA?\fP"
-Siemens A1 for its default SMS center. Situation with undeterminable SMS center
-is unrecoverable and casues immediate fail. It is a common practice to use
-plus sign ("\fB+\fP") to indicate international number type.
-Known SMS centers as of May 1999:
-.RS
-.TP
-.BR "CZ Paegas " ( "230 01" "): " +420603052000
-.TP
-.BR "CZ EuroTel " ( "230 02" "): " +420602909909
-.RE
-.TP
-.BR -m | --maxretry\  < # >
-Maximum retries of any \fBAT\fP-style command during the session. All the
-retries are summed during one run of
-.B mdsms
-and no more retries of the command are permitted. After exceeding this
-value the program is terminated.
-.TP
-.BR -r | --readtime\  < sec >
-Maximum response read timeout before give up.
-.B mdsms
-sends the requested \fBAT\fP-style command to
-.B MobilDock
-and expects response. Unfortunately when the voice call is in progress,
-.B MobilDock
-will block any serial device communication and it is impossible to differentiate
-between calling
-.B MobilDock
-and stucked/disconnected one. After exceeding this time interval,
-.B mdsms
-is terminated immediately,
-.B maxretry
-parameter notwithstanding. Standard value is
-.BR DEF_READTIME
-seconds and should be enough for any voice call.
-.TP
-.BR -t | --chartime\  < msec >
-Although the fixed used baudrate of
-.B 19200
-is pretty low, MobilDock/Siemens A1 couple
-.RB "aren't"
-able to accept steady
-stream of data at this speed. Even the used XON/XOFF handshaking is just not
-enough. The only possible workaround is to slowdown the communication by
-waiting a bit after character sent to give relax time to these devices.
-When full rate communication was used, occasional longer SMS data corruption
-was observed. Argument is given in milliseconds and its default value is
-.BR DEF_CHARTIME ms.
-.TP
-.BR -T | --cmdtime\  < msec >
-This delay is given before sending any
-.B AT-style
-command to MobilDock/Siemens A1.
-Its primary purpose is to let any previous entered commands to finish and
-to clear any input before actually sending our own command. Also all Siemens
-devices are known that they strongly dislike fast edge-to-edge communication
-and to satisfy these requirements this delay was considered as the best
-approach. The default value is
-.BR DEF_CMDTIME ms.
-.TP
-.BR -f | --file
-When parameter <\fBmsg text\fP> has been specified, by using this option
-\fBmdsms\fP will read the file with the <\fBmsg text\fP> filename instead
-and send its \fBcontents\fP as the SMS message.
-.TP
-.BR -v | --verbose
-Increase verbosity level by one. Currently the maximum defined level is
-.BR 3 ,
-the default value is
-.BR 0 .
-.TP
-.BR -h | --help
-Give short parameters description to
-.I stderr
-(standard error output stream).
-.TP
-.BR -V | --version
-Print the version number and exit.
-.TP
-.RB < "dest. phone" >
-This mandatory parameter specifies the telephone number of the recipient
-of SMS message. International prefix character plus
-.RB ( + )
-is supported the national mode without plus
-.RB ( + )
-prefix is supported and the meaning is specific to the GSM operator currently
-being roamed in (NOT the native
-.RB "'home'"
-operator of the SIM card!).
-This number can be made default in system configuration files, see below
-for section
-.BR CONFIGURATION .
-.TP
-.RB < "msg text" >
-Here you write the exact body of the message. This parameter should be
-specified only as one component, although if more found they are concatenated
-with separating space (" "). But this practice is discouraged as
-your shell will probably remove any multiple spaces found and also other
-metacharacters may be incorrectly interpreted. To prevent any escaping
-mess, you may prefer to omit this parameter and the the message text is
-then read from
-.I stdin
-(standard input stream).
-
-.SH CONFIGURATION
-.B mdsms
-reads ~\fB     CONFIG_MAIN     \fP~ followed by ~\fB$HOME      CONFIG_HOME     \fP~
-configuration files. The content of these files (and also any file read by
-.BR -c | --config
-option)
-has the usual
-.BR getopt (3)
-syntax with dashes. Newlines are taken as whitespace, both double ("\fB~\fP")
-and single ("\fB'\fP")
-quoting is supported. Embedded quote characters can be escaped by backslash
-("\fB\\\fP").
-Arguments are processes in order as specified in configuration files and
-finally the command-line of the program itself, overriding any previous
-values.  Although the order of
-.BR -c | --config
-options on one line is preserved the first file is read AFTER all of the
-current options are processed. Recursive use of
-.B -c
-is permitted and the files are read in LIFO (Last-In First-Out, AKA stack)
-order. You should use "\fB-v -v\fP"
-to see details of option processing with more complex configuration setups.
-
-.SH OPERATION
-Upon startup
-.B mdsms
-locks the port (see option
-.BR -l | --lockfile
-for details) and opens the serial device with hardcoded parameters of
-19200 baud, software handshaking (XON/XOFF style), 8 bits, no parity.
-Then issues the following commands:
-.TP
-.BR AT <CTRL-Z>
-.B AT
-is used to fool MobilDock and pass the following
-.B <CTRL-Z>
-(ascii decimal code 26) character to Siemens A1 and break it from eventual
-.B AT+CMGS
-mode in which it may errorneously remain from previous sessions.
-.TP
-.B AT
-Test the responsiveness of Siemens A1.
-.TP
-\fBAT+CSCA="\fPsmc # from user\fB"\fP
-This command is omitted if
-.B "smsc #"
-is not specified by user (or specified/overriden as empty string \fB""\fP
-.TP
-\fBAT+CSCA?\fP
-Query the currently set SMC center number to include it later to the
-header of SMS PDU format where it is required. If \fBAT+CSCA="\fP...\fB"\fP
-was issued before, this number should match it but no sanity checks are
-currently do so.
-.TP
-\fBAT+CMGF=0\fP
-Set the default SMS message format to PDU type. Currently Siemens A1
-.RB "doesn't"
-support any other SMS format anyway.
-.TP
-\fBAT+CMGS=\fP# chars
-This command physically sends the message and the resulting "\fB+CMGS:\fP" output
-is catched and returned as
-.B MR
-(message reference) number to the user.
-.TP
-\fBAT\fP
-Check that Siemens A1 survived the sending of the message.
-
-.SH SEE ALSO
-.TP
-.B GSM 03.40
-ETSI documentation for SMS messages in GSM networks
-.TP
-.B "Developers'" Guide: SMS with the A1
-Tech note on PDU SMS format etc:
-.B http:/              /www.siemens.se/telefoner/ovrigtgsm/fragorsvar/a1_sms.pdf
-.TP
-.B Technical Description of the Siemens A1
-Siemens A1 command description
-.B http:/              /www.siemens.se/telefoner/ovrigtgsm/fragorsvar/a1_manual.pdf
-
-.SH FILES
-.TP
-\fB    CONFIG_MAIN     \fP
-Main configuration file
-.TP
-\fB$HOME       CONFIG_HOME     \fP
-User personalized local configuration file
-
-.SH AUTHOR
-.B mdsms
-was written by Jan Kratochvil who should be responsible for all the bugs
-included. Please see the file "\fBAUTHORS\fP"
-shipped with the original distribution archive for more details.