* $Id$
- *
- * $Log$
- * Revision 1.5 1999/07/03 18:56:49 short
- * Documentation fixes.
- *
- * Revision 1.4 1999/06/03 11:46:41 short
- * Logging (--log) implemented.
- *
- * Revision 1.3 1999/06/03 10:52:32 short
- * Commented all the entries in setup.h.
- *
- * Revision 1.2 1999/06/03 10:38:52 short
- * Implemented remaining communication timeouts and maximum retry count.
- *
- * Revision 1.1.1.1 1999/05/26 13:06:26 short
- * First alpha release.
- *
*/
#define CONFIG_MAIN "/etc/" PACKAGE "rc" /* global configuration file */
#define CONFIG_HOME "/." PACKAGE "rc" /* user-local cfg file,
$HOME is prepended automatically */
-#define DEF_DEVICE "/dev/mobildock" /* --device default */
+#define DEF_DEVICE "/dev/nokia9110" /* --device default */
#define DEF_LOGNAME "" /* --log default */
#ifndef DEF_LOCKFILE
#define DEF_LOCKFILE "/var/lock/LCK..%s" /* --lockfile default */
#endif
-#define DEF_MAXRETRY 10 /* --maxretry default */
-#define DEF_READTIME 60*60 /* --readtime default */
+#define DEF_BAUD 19200 /* --baud default */
+#define DEF_MAXRETRY 3 /* --maxretry default */
+#define DEF_READTIME 5 /* --readtime default */
#define DEF_CHARTIME 10 /* --chartime default
(500ms per 80char=6.25ms recommended by Siemens */
#define DEF_CMDTIME 500 /* --cmdtime default */
+#define WORD_NET "net" /* load as network logo */
+#define WORD_GROUP "group" /* load as group graphics */
#define MAXCONFIG 4096 /* maximum allowed size of any configuration file */
#define MAXCFGARGS 256 /* maximum allowed number of arguments in cfg file */
#define MAXCFGLOOP 5 /* maximum number of recursive opens in cfg files */
this parameter taken in seconds */
#define ADDR_NAT 0x81 /* PDU address type for non-'+' numbers */
#define ADDR_INT 0x91 /* PDU address type for numbers prefixed by '+' */
-#define PDU_TYPE 0x11 /* first byte of PDU, SMS submit */
-#define PDU_MR 0x00 /* default message reference, filled by Siemens A1 */
-#define PDU_PID 0x00 /* PDU protocol identifier, SMS message type */
-#define PDU_DCS 0x00 /* PDU Data Coding Scheme, 7-bit class-2 message */
-#define PDU_VP 0xFF /* PDU Validity Period, maximum relative time */
#define MAXNUMLEN 20 /* maximum number of digits in GSM number */
#define MAXBODYLEN 160 /* maximum length of characters in SMS body */
#define BODYLOAD 200 /* number of bytes to read when body not on command line */