From: short <> Date: Sat, 7 Apr 2001 19:20:13 +0000 (+0000) Subject: Described options implemented in current mdsms.c:1.19->1.20 change: X-Git-Tag: rel_1_5_1~7 X-Git-Url: http://git.jankratochvil.net/?p=mdsms.git;a=commitdiff_plain;h=f6a72aa065bb6df88fef22a1d371ea1ffff56c6e;ds=inline Described options implemented in current mdsms.c:1.19->1.20 change: -x/--xonxoff -C/--rtscts -M/--smsmode -P/--pdusmscmode Various typos fixed. SMS center # added for: 230 03 Siemens M20 and M1 (M1 untested...) listed as supported devices --- diff --git a/mdsms.1.in b/mdsms.1.in index a5b9823..ded0992 100644 --- a/mdsms.1.in +++ b/mdsms.1.in @@ -46,13 +46,22 @@ device connected through the serial port. Currently supported: .RS .TP .B Nokia Communicator 9000/9000i -All modes except \fB--logo-send\fP supported. +All modes except \fB--logo-send\fP/\fB--ring-send\fP supported. .TP .B Nokia Communicator 9110 -All modes supported. This is the only device with \fB--logo-send\fP capability for now. +All modes supported. This is the only device with \fB--logo-send\fP/\fB--ring-send\fP capability for now. .TP .B Siemens A1 -Firmware revision 2.0 required. All modes except \fB--logo-send\fP supported. +Firmware revision 2.0 required. All modes except \fB--logo-send\fP/\fB--ring-send\fP supported. +These modes \fBcould\fP be supported for this device but unfortunately +.B mdsms +currently does not support it. +.TP +.B Siemens M20, M1 +All modes except \fB--logo-send\fP/\fB--ring-send\fP supported. +These modes \fBcould\fP be supported for this device but unfortunately +.B mdsms +currently does not support it. .RE .SH OPTIONS @@ -76,6 +85,15 @@ etc., similar to output of If set to empty string (which is default - ~\fB DEF_LOGNAME \fP~), nothing is logged anywhere. .TP +.BR -l | --lockfile\ < lockfile > +Prior to accessing serial device specified above the lockfile should be +acquired for correct concurrent processes behaviour. Although this name +can be given as direct filename more common method is to use pattern +with embedded "\fB%s\fP" where this mark is replaced by actual basename +(last component of pathname with all preceding directory names stripped) +of serial device used. +Default name for lockfile is ~\fB DEF_LOCKFILE \fP~. +.TP .BR -b | --baud\ < rate > Sets custom baudrate for accessing Nokia modem. Supported speeds are currently: \fB2400\fP, @@ -85,14 +103,60 @@ Sets custom baudrate for accessing Nokia modem. Supported speeds are currently: \fB38400\fP, \fB57600\fP. Default is \fB DEF_BAUD \fP. .TP -.BR -l | --lockfile\ < lockfile > -Prior to accessing serial device specified above the lockfile should be -acquired for correct concurrent processes behaviour. Although this name -can be given as direct filename more common method is to use pattern -with embedded "\fB%s\fP" where this mark is replaced by actual basename -(last component of pathname with all preceding directory names stripped) -of serial device used. -Default name for lockfile is ~\fB DEF_LOCKFILE \fP~. +.BR -x | --xonxoff +Turns handshaking mode to \fBXON/XOFF\fP (also called \fBsoftware handshaking\fP). +Use this mode if you are using only 3-wire serial cable. Device should be +configured in "\fBAT+IFC=1,1\fP" mode, if \fBAT+IFC\fP command supported. When +possible, you should rather use \fBRTS/CTS\fP handshaking described in the +following paragraph. This mode is the default one. +.TP +.BR -C | --rtscts +Turns handshaking mode to \fBRTS/CTS\fP (also called \fBhardware handshaking\fP). +Use this mode if you are using full 7-wire (approx.) serial cable. Device should be +configured in "\fBAT+IFC=2,2\fP" mode, if \fBAT+IFC\fP command supported. Try +to use this mode whenever possible (instead of the default \fBXON/XOFF\fP mode described +in the previous paragraph). This mode may not be available in your UNIX flavour. +.TP +.BR -M | --smsmode +Forces the SMS mode to use - either \fBpdu\fP or \fB text\fP mode. By default +.B mdsms +tries to detect mode to use automatically, \fBPDU\fP mode is preferred. When +your modem is capable of both modes and you need for some reasone \fBtext\fP +mode, you may use \fB--smsmode text\fP argument to force it. \fBPDU\fP mode +is recommended for unattended operation, on the other side \fBtext\fP mode +should be more compatible when you have compatibility problems with unsupported +GSM modem. It is recommended to force the exact mode you will be using in +unattanded operaton. By such way you will prevent failures caused by the other +mode after possible random communication glitches (and therefore automatic +.B mdsms +switchover). +.TP +.BR -P | --pdusmscmode +Forces SMS center prepending mode for \fBPDU mode\fP operation. By default +.B mdsms +tries sequentially all the described modes, you should lock it for +unattanded operation to prevent vain switchovers from random communication +glitches (also you will notice faster response for "\fBcount-out\fP" or +"\fBnone\fP" modes): +.RS +.TP +.BR count-in +The default mode, SMS center is prepended to the \fBPDU\fP and SMS +.RB "center's" +length is taken into account during length calculation for "\fBAT+CMGS=\fP#". +.TP +.BR count-out +SMS center is prepended to the \fBPDU\fP but SMS +.RB "center's" +length is omitted +during length calculation for "\fBAT+CMGS=\fP#". +.TP +.BR none +SMS center is \fBNOT\fP prepended to the \fBPDU\fP, SMS center to use by +GSM modem is taken from the one set by +\fBAT+CSCA="\fPsmsc # from user\fB"\fP +command. +.RE .TP .BR -s | --smsc\ < smsc\ # > Specify custom SMS center number. If not specified (or overriden as empty @@ -100,14 +164,17 @@ string by \fB-s ""\fP) .B mdsms asks by "\fBAT+CSCA?\fP" for the current default SMS center. Situation with undeterminable SMS center -is unrecoverable and casues immediate fail. It is a common practice to use +is unrecoverable and causes immediate fail. Please contact your GSM operator +customer service if you are in trouble. It is a common practice to use plus sign ("\fB+\fP") to indicate international number type. -Known SMS centers as of May 1999: +Known SMS centers as of April 2001: .RS .TP -.BR "CZ Paegas " ( "230 01" "): " +420603052000 +.BR "CZ Paegas " ( "230 01" "): " +420603052000 .TP .BR "CZ EuroTel " ( "230 02" "): " +420602909909 +.TP +.BR "CZ Oskar " ( "230 03" "): " +420608005681 .RE .TP .BR -m | --maxretry\ < # > @@ -296,13 +363,13 @@ mode in which it may errorneously remain from previous sessions. .B AT Test the responsiveness of the device. .TP -\fBAT+CSCA="\fPsmc # from user\fB"\fP +\fBAT+CSCA="\fPsmsc # from user\fB"\fP This command is omitted if .B "smsc #" is not specified by user (or specified/overriden as empty string \fB""\fP .TP \fBAT+CSCA?\fP -Query the currently set SMC center number to include it later to the +Query the currently set SMS center number to include it later to the header of SMS PDU format where it is required. If \fBAT+CSCA="\fP...\fB"\fP was issued before, this number should match it but no sanity checks are currently do so. Also it is used to detect possibly unset SMS center.