/* * $Id$ * * $Log$ * Revision 1.5 1999/07/03 18:56:49 short * Documentation fixes. * * Revision 1.4 1999/06/03 11:46:41 short * Logging (--log) implemented. * * Revision 1.3 1999/06/03 10:52:32 short * Commented all the entries in setup.h. * * Revision 1.2 1999/06/03 10:38:52 short * Implemented remaining communication timeouts and maximum retry count. * * Revision 1.1.1.1 1999/05/26 13:06:26 short * First alpha release. * */ #define CONFIG_MAIN "/etc/" PACKAGE "rc" /* global configuration file */ #define CONFIG_HOME "/." PACKAGE "rc" /* user-local cfg file, $HOME is prepended automatically */ #define DEF_DEVICE "/dev/mobildock" /* --device default */ #define DEF_LOGNAME "" /* --log default */ #ifndef DEF_LOCKFILE #define DEF_LOCKFILE "/var/lock/LCK..%s" /* --lockfile default */ #endif #define DEF_MAXRETRY 10 /* --maxretry default */ #define DEF_READTIME 60*60 /* --readtime default */ #define DEF_CHARTIME 10 /* --chartime default (500ms per 80char=6.25ms recommended by Siemens */ #define DEF_CMDTIME 500 /* --cmdtime default */ #define MAXCONFIG 4096 /* maximum allowed size of any configuration file */ #define MAXCFGARGS 256 /* maximum allowed number of arguments in cfg file */ #define MAXCFGLOOP 5 /* maximum number of recursive opens in cfg files */ #define MAXCFGNUM 20 /* total maximum number of cfgs read during one run */ #define DEVLOCK_PERIOD 2 /* seconds between attempts to obtain a lockfile */ #define DEVLOCK_MAXEMPTY 1 /* seconds to wait while lockfile is empty to prevent races during lock creation */ #define MAXSENDTIME 2 /* max. allowed number of seconds for sending one char */ #define LOCKREPORT 15 /* report to logfile if device lock took more than this parameter taken in seconds */ #define ADDR_NAT 0x81 /* PDU address type for non-'+' numbers */ #define ADDR_INT 0x91 /* PDU address type for numbers prefixed by '+' */ #define PDU_TYPE 0x11 /* first byte of PDU, SMS submit */ #define PDU_MR 0x00 /* default message reference, filled by Siemens A1 */ #define PDU_PID 0x00 /* PDU protocol identifier, SMS message type */ #define PDU_DCS 0x00 /* PDU Data Coding Scheme, 7-bit class-2 message */ #define PDU_VP 0xFF /* PDU Validity Period, maximum relative time */ #define MAXNUMLEN 20 /* maximum number of digits in GSM number */ #define MAXBODYLEN 160 /* maximum length of characters in SMS body */ #define BODYLOAD 200 /* number of bytes to read when body not on command line */ #define ERROR_SUBSTR1 "ERROR" /* first failure ind. substring in A1 response */ #define ERROR_SUBSTR2 "\nError:" /* second such, this one from MobilDock */